4–5 · Specification & Installation
Unified Product Specification & Installation Topologies
One product exists: the Black laser-engraved Denka® Platinum Plate. All specifications, laboratory results and field data apply to it.
4 · Specifications
| 4.1 | Product | Denka® Platinum Plate (Black Laser-Engraved) |
| 4.2 | Function | Passive high-frequency conducted-noise filter |
| 4.3 | Dimensions | 50 mm × 25 mm × 3.5 mm |
| 4.4 | Weight | approx. 21 g |
| 4.5 | Material | Ni-Zn ferrite / sintered ceramic composite (grade DT400L), black laser-engraved |
| 4.6 | Design band | 150 kHz – 30 MHz (CISPR 11 conducted-emission band) |
| 4.7 | HF attenuation | 13–15% (≈1.2–1.4 dB) per plate at 25–30 MHz — KU Leuven / EnergyVille, Nov 2022 |
| 4.8 | Self-heating | ≤ 0.4 °C under high-frequency noise absorption |
| 4.9 | Electrical | High-resistivity ceramic; no galvanic connection to conductors |
| 4.10 | Temperature rating | None |
| 4.11 | Maintenance | None — no consumables or moving parts; chemically stable ceramic |
| 4.12 | Environmental | Non-radioactive, asbestos-free, halogen-free, RoHS compliant |
| 4.13 | Lifespan & warranty | 25+ Years |
| 4.14 | Guarantee | 90-Day Result-Conditioned Money-Back Guarantee |
5.1 · Distribution-level installation
On phase-conductor outputs of circuit breakers feeding non-linear loads (VFDs, rectifiers, SMPS panels, PV inverters). Limits propagation of HF emissions into the wider network.
5.2 · Motor-level installation (bearing protection)
On motor cables at the drive output to suppress HF common-mode currents that would otherwise discharge through motor bearings.[11[11] Liu, 2014Bearing currents in inverter-fed motors.,12[12] Erdman et al., 1996Effect of PWM inverters on AC motor bearing currents and shaft voltages. IEEE Trans. Industry Applications.,13[13] ABB Technical Guide No. 5Bearing currents in modern AC drive systems.]
5.3 · Safety protocol
NFPA 70E
Clip-on retrofit with zero rewiring and no galvanic connection. Installed by qualified personnel per local switchgear safety regulations (e.g. NFPA 70E) during routine maintenance windows.[17[17] NFPA 70EStandard for electrical safety in the workplace.]
5.4 · Plate allocation rule
Plate quantities are never quoted from a catalogue. They come from a site survey or the site's single-line diagram (SLD) — very large plants can need thousands of plates — and every plan is built panel by panel.
Which panels
Only end-user (EU) panels are fitted — the panels whose breakers feed electrical loads directly. Panels that distribute to other panels (MDBs, SMDBs) are not fitted.
1 / phase / conductor · ≥ 60 A
Unit rule: 1 Denka® plate per phase conductor on each breaker rated about 60 A and above. Parallel conductors on the same phase each receive their own plate.
- A
All outgoing breakers below 60 A
Fit the panel's principal (incoming) breaker only — it covers every circuit in the panel.
- B
Mixed: some 60 A and above, some below
Fit each breaker of 60 A and above individually, and fit the principal breaker to cover the smaller circuits.
- C
All outgoing breakers 60 A and above
Fit every outgoing breaker. The principal breaker is not fitted, because every circuit is already covered.