Unified Product Specification & Installation Topologies

One product exists: the Black laser-engraved Denka® Platinum Plate. All specifications, laboratory results and field data apply to it.

4 · Specifications

4.1ProductDenka® Platinum Plate (Black Laser-Engraved)
4.2FunctionPassive high-frequency conducted-noise filter
4.3Dimensions50 mm × 25 mm × 3.5 mm
4.4Weightapprox. 21 g
4.5MaterialNi-Zn ferrite / sintered ceramic composite (grade DT400L), black laser-engraved
4.6Design band150 kHz – 30 MHz (CISPR 11 conducted-emission band)
4.7HF attenuation13–15% (≈1.2–1.4 dB) per plate at 25–30 MHz — KU Leuven / EnergyVille, Nov 2022
4.8Self-heating≤ 0.4 °C under high-frequency noise absorption
4.9ElectricalHigh-resistivity ceramic; no galvanic connection to conductors
4.10Temperature ratingNone
4.11MaintenanceNone — no consumables or moving parts; chemically stable ceramic
4.12EnvironmentalNon-radioactive, asbestos-free, halogen-free, RoHS compliant
4.13Lifespan & warranty25+ Years
4.14Guarantee90-Day Result-Conditioned Money-Back Guarantee
SCOPE
Scope: Denka® Platinum Plates are a high-frequency filter. They complement, and do not replace, IEEE 519 low-order harmonic filters and capacitor power-factor correction.[1,2]

5.1 · Distribution-level installation

On phase-conductor outputs of circuit breakers feeding non-linear loads (VFDs, rectifiers, SMPS panels, PV inverters). Limits propagation of HF emissions into the wider network.

SupplyBreakerNon-linear loadVFD · SMPS · PV · rectifierL1L2L3Denka® platesHF ←

5.2 · Motor-level installation (bearing protection)

On motor cables at the drive output to suppress HF common-mode currents that would otherwise discharge through motor bearings.[11,12,13]

VFDDenka® platesMotorBearing current path

5.3 · Safety protocol

NFPA 70E

Clip-on retrofit with zero rewiring and no galvanic connection. Installed by qualified personnel per local switchgear safety regulations (e.g. NFPA 70E) during routine maintenance windows.[17]

5.4 · Plate allocation rule

Plate quantities are never quoted from a catalogue. They come from a site survey or the site's single-line diagram (SLD) — very large plants can need thousands of plates — and every plan is built panel by panel.

Which panels

Only end-user (EU) panels are fitted — the panels whose breakers feed electrical loads directly. Panels that distribute to other panels (MDBs, SMDBs) are not fitted.

1 / phase / conductor · ≥ 60 A

Unit rule: 1 Denka® plate per phase conductor on each breaker rated about 60 A and above. Parallel conductors on the same phase each receive their own plate.

  1. A

    All outgoing breakers below 60 A

    Fit the panel's principal (incoming) breaker only — it covers every circuit in the panel.

  2. B

    Mixed: some 60 A and above, some below

    Fit each breaker of 60 A and above individually, and fit the principal breaker to cover the smaller circuits.

  3. C

    All outgoing breakers 60 A and above

    Fit every outgoing breaker. The principal breaker is not fitted, because every circuit is already covered.

EU PANEL 1100 APrincipalfitted16 A32 A40 AA · All outgoing breakers below 60 A3 × Denka® (3-phase)EU PANEL 2250 APrincipalfitted125 A63 A32 A16 AB · Mixed: some 60 A and above, some below9 × Denka® (3-phase)EU PANEL 3630 APrincipalnot fitted250 A160 A100 AC · All outgoing breakers 60 A and above9 × Denka® (3-phase)
NOTE
Plan the whole site from the SLD or a survey, then apply the rule panel by panel with the panel planner in Engineering tools. → Panel planner (end-user panel)