Skip to content
All case studies
Food & beverage

Nestlé Waters — Ma'an bottling facility

After Denka® Platinum Plates went online on 1 July 2026, measured specific energy consumption came in 14.7% below the adjusted baseline over July–August — 134,693 kWh avoided, with a 20.8% reduction in August alone.

WHY Energy Services Consulting carried out the Measurement & Verification for Nestlé Waters Jordan at the Ma'an facility, using specific energy consumption (SEC = facility kWh ÷ production m³) so results are normalised for production.

  • Average saving, July–August 2026: 14.7% against the adjusted baseline
  • Energy avoided: 134,693 kWh in two peak-summer months
  • August 2026: SEC 57.42 → 45.46 kWh/m³ expected vs. actual (−20.8%)
  • July 2026 (commissioning): SEC 52.08 → 48.38 kWh/m³ (−7.1%)

Baseline. Before installation the plant's SEC had drifted from 37.74 kWh/m³ (H1 2025) to 46.58 kWh/m³ (H1 2026) — 23.4% less efficient. That degradation factor was applied to 2025 summer data to set the expected 2026 baseline.

Scope note. These are the first two months of the reporting period; the consultant recommends extending M&V to September–October 2026 to confirm the savings stay stable.

Client confirmation. Nestlé Waters Jordan has confirmed this M&V report.